Sulfate Removal Nanofiltration Membrane

SL Lithium NF 8040 HS 50
SL Lithium NF 8040 HS 50 Sulfate Removal Nanofiltration Membrane has a higher removal rate of sulfate in brine with a lower removal rate of calcium and magnesium, therefore, scales including calcium sulfate ones can be avoided. This sulfate nanofiltration membrane with good selectivity is used to accurately control the removal of sulfate to ensure a high removal rate of sulfate ions, then guarantees that sulfate and other hetero-ions can be effectively separated in the process of lithium extraction from salt lake.
Specifications
ModelMaterialArea / pcsApplication PressureGrid ThicknessDesalination Rate%
SL Lithium NF 8040 HS 50FRP365ft2/34m2600psi30mil98.5

Note:

1. Membrane flux and its desalination rate is based on following test conditions: 2000ppmMgSO4, 70psi (4.8bar), 77℉ (25℃), 15% recovery rate.

2. The water yield of a single element may vary within a range of ±25%.

3. The stable desalination rate is normally achieved within 36 - 72 hours of continuous operation, depending on feeding features and operating conditions.

4. Sales specifications for this product may change slightly in accordance with design optimisation

5. Guaranteed active area ±5%.

Component size
Model

size(in./ cm.*)

ABC

Packing weight LBS/Kg
SL Lithium NF 8040 HS 5040.0/101.6   1.125/2.86    7.9/20.135/16

Note:

Membrane element fit into pressure vessels with engineered internal diameter of 8 in (20.3cm).  *1in=2.54cm

Run and wash parameterss
Operation flux range15~40LMH
Maximum operating pressure1600psi (41bar)
Maximum temperature tolerance2122°F (50°C)
Maximum tolerable pHContinuous operation2:3 – 10
CIP:2 – 11
Maximum pressure drop15psi (1.0bar)
Maximum chlorine tolerance3<0.1 ppm
Influent water quality requirementsNTU < 1    SDI15 < 5

Note:

1. If the temperature is higher than 95°F (35°C), the maximum withstand pressure is 435psi (30bar).

2. The highest operating temperature is 95℉ (35℃) when pH value is higher than 10.

3. Under certain circumstances, free chlorine and other oxidising agents can cause premature failure of membranes, therefore, it is recommended to remove free chlorine before it contacts with membranes.

  • Preparations

    When the membrane system is ready to be commissioned, the membrane treatment system needs to be started up correctly to prevent damages to membrane elements caused by the overflow of feeding water and the hydraulic shock. The correct initiating sequence helps to ensure that the system’s operating parameters align with design requirements, so that the quality and quantity of produced water through the system reach designed objectives.

    Before the membrane system is initiated for the first time, pretreatment system debugging, elements loading, instrumentation debugging and calibration and ancillary equipment system debugging and so on shall be completed.

    Please contact us for more information.

    For more information, please contact us

  • Operation Guide

    During start-up, shutdown, cleaning, etc., to prevent potential damaged to membranes, any sudden changes of pressures or of crossflow flow in membrane elements shall be avoided. During start-up, it is suggested to follow the undermentioned procedures to gradually transit the system from shutdown to operating:

    Feeding pressure should be gradually escalated over a period of 30 ~ 90 seconds.

    The set peak of crossflow velocity should be gradually achieved over a period of 30~ 60 seconds.

    For more information, please contact us

  • Maintenance

    Once the membrane element is moisturized, it should always be kept moist.

    If users failed to strictly follow the set operating limitations, the warranty will be null.

    If the system need to be shut down for an extended period of time, it is recommended to immerse the membrane elements in protective solution to prevent microorganisms.

    The user shall be responsible for any damages to the membrane elements caused by using incompatible chemicals, lubricants, etc.

    The maximum pressure drop a single pressure vessel can tolerate is 50psi (3.4bar).

    Under all circumstances, backpressure must be avoided on the production side of the membrane system.